The introduction of FLIR System (Hongkong) ThermaCAM gasFind IR gas leak detector has allowed companies to incorporate infrared into their leak detection and repair programmes (LDAR) providing a far quicker and more efficient method than traditional toxic vapour analysis.
This success has led to further product development and the introduction of an infrared camera specifically for detecting greenhouse gasesthet are not visible in the mid-wave infrared band; Sulphur hexafluoride and anhydrous ammonia are typical examples. This new camera is the ThermaCAM GasFind IR LW. It is based on the standard model but as its suffix suggest it operates in the longwave infrared band.
Sulphur hexafluoride (SF6) is a relatively expensive man-made chemical released by electrical substations where it is used as an electrical insulator in equipment that transmits and distributes electricity. It is also used as a cover gas in the magnesium industry, in the manufacture of semiconductors, for thermal and sound insulation, as a tracer gas for vebtilation efficiency and in medical applications. Although Sulphur hexafluoride is extensively recycled leakage is still a concern. excessive exposure can harm human health and of the internationally monitored greenhouse gases it has, by far, the greatest global warming potential- 23,000 times that of CO2. This gas is included in the European Pollutant Emission register, a vast database that catalogues European industrial pollution. It requires affected industrial plants to indentify leaks from a range of 50 pollutants that they emit into the air or water in quantites over a given threshold. The ThermaCAM GasFind IR LW allows plant managers to see, and hence, reduce the emission of SF6 with ease. Although the detection of Sulphur hexafluoride is a key selling point for this new camera it is not by any means the only gas that it can detect. It is designed to see a wide range of other gases too including anhydrous ammonia tha is widely used as a refrigerant in large cold-storage facilities.
The new ThermaCAM GasFind IR LW actually shows any leakage point or points of SF6 gas in real time. It can detect small leaks from several metres away and big leaks from hundreds of metres away and in trials has proved able to see leaks that have eluded a traditional active laser system. In addition to making leaks visible, the camera is able to scan large areas quickly, greatly increasing inspection speed and improving overall plant safety. It can also be used without stopping any operation or process
Monday, September 28, 2009
The ThermaCAM GasFind IR LW Sees Sulphur Hexafluoride (SF6)
Posted by besar at 9:52 PM 0 comments
Thursday, September 24, 2009
WolfPack Area Monitor for indoor Air Quality (IAQ)
GrayWolf Sensing Solutions introduces a new Area Monitor for Indoor Air Quality (IAQ) and for other environmental monitoring applications. The WolfPack is a fully modular system: plug in one, up to three Graywolf DirectSense probes with up to six sensors installed per probe. Add a particle counter, airspeed probe, or other sensors: up to 21 parameters may be monitored simultaneously. The same probes, as part of the modular design, may alternately be connected to a windows Mobile Pocket PC or vista OS mobile PC for hand-held, walkthrough surveys, spot checking and spot logging.
Available parameters include : TVOCs, Carbon Dioxide, %RH, 'C/'F, particulates, auto-zeroing Differential Pressure and Air Velocity. sensors for these parameters all exhibit rapid response and are highly accurate. In addition, up to 18 specific electrochemical gas sensors (CO, O3, NH3, NO2, NO, H2S, SO2, Cl2, HCN, HCl, etc) are available.
The WolfPack has a tactile color screen and is powered by an embedded WinCE operating system running GrayWolf's 2009 application software. Wolfsense 2009 offers a broad range of user-friendly features . A unique workflow feature handholds users through data-logging set-up; easily costumized for very specific applications, allowing less experienced operators to take advantage of more advanced functions. On-board features also include: Video help, Parameter details (typical source, typical background levels, health effects,etc..), sensor info (basic sensor care, cross-interferences, specifications,etc), application related documents, In-situ text notation, In-situ audio notation..and much more.
Once measurements have been trend-logged over time; review, analyze, and report on the data and field-collected notes with the included WolfSense PC software. Optional Advanced report generator software automates the entire reporting process.
Posted by besar at 11:29 PM 0 comments
Wednesday, September 23, 2009
H2Scan Corporation Receives The Korea Occupational Safety & Health Agency (KOSHA) Certificate
H2Scan Corporation (USA) announce the Company has received a Certificate of Compliance from the korea Occupational Safety & health Agency (KOSHA) for its HY ALERTA(TM) 1600 Instrinsically Safe Area Hydrogen Monitor and HY-OPTIMA(Tm) 1700 Intrinsically Safe Process Hydrogen Analyser. they are also ATEX Certified (Atmosphere Explosive).
H2scan's Vice President of Sales and Business Development Cyril Berg stated, "Having these two units receive the KOSHA certificated of Compliance in addition to their current ATEX certification is an important step for us to penetrate the Korean market. It will provide us and our Korean distributor, young heung coporation, the necessary leverage in selling these product."
H2scan's HY-ALERTA 1600 intrinsically Safe Area Hydrogen Monitor provides fixed area hydrogen specific measurement for hydrogen concentrations as low as 4000 ppm and can be scaled to any concentration up to 5% hydrogen by volume. Additionally, its hydrogen specific sensor technology has no cross sensitivity to other combustible gases, thus eliminating false alarms and ensuring safety system reliability. With a 10 year product life expectancy, it also proves to be fiscally prudent.
Posted by besar at 11:19 PM 0 comments
Thermo Fisher Scientific Launch Compact Modular Total Nitrogen/Sulfur/Chlorine Analyser
Thermo Fisher Scientific (USA) launch the new TITAN 4000 Total Nitrogen/Sulfur/Chlorine (NSX) analyser. This streamline NSX analyser, up to 60% smaller than competing analyser, offers users in the refinery and petrochemical makets superior sample introduction and enhanced oxidative combustion performance. Its innovative detector enable increased analysis speed and productivity, as well as maximum accuracy and reliability of results. Its extensive working range covers total nitrogen/sulphur/chlorine applications from low ppb (part per million) concentrations. in addition, the use of a powerful combustion method allows the analyser to cater for a wide range of applications in refinery and chemical samples, including naphtha, aromatics, automotive fuels, biodiesel fuels, gaseous, and LPG samples.
In order to ensure optimum productivity within today's global market, the fast reporting of total sulphur, nitrogen and chlorine content data, coupled with superior analytical is essential. Traditional analysers achieve times of six minutes, requiring extra carrier gas facilities and frequent system check, the innovative thermo Scientific TITAN 4000 NSX analyser is capable of analysing TN/TS samples within an unsurpassed two minutes and TX samples in under four minutes.
By operating in real time and with minimal sample handling requirements, the TITAN 4000 analyser decreases analytical cost and complies with current market driven ASTM, IP and UOP methods. The powerful new analyser features a unique, patent-pending chromium plated copper spray injection design, which is able to inject high boiling point component samples without blocking the injection system. The sample introduction and combustion technology, with pre-soot detection(patent pending), ensures optimum analysis and result precision, reducing lead time and minimising matrix effect.
Contrary to other technologies , The TITAN 4000 injection port and the plugflow quartz combustion tube require only oxygen gas. Maintenance is reduced through removing the need for their frequent replacement. A heated filter and a number of gasflow and temperature control sensors further eliminate the need for user interaction. These features improve the autonomy of the system and reduce instrument downtime and maintenance. minimising operation costs associated with gas consumption and consumables. In addtion, the combination of safe, sensitive and realiable TS-UVF, TN-CLD, microcoulometric techniques and reduced instrument interaction lead to heightened laboratory safety.
Posted by besar at 10:26 PM 0 comments
Wednesday, September 9, 2009
Free Multimedia Guide for Karl Fischer Titration
As common as Karl Fischer titration might be in labs around the world, there remain tricky questions such as "How often should I change the molecular sieve?" or " How can i improve the solubility of my sample?", to mention just two. Metrohm's free multimedia guide for Karl Fischer titration provides the answer - plus a wealth of other practical advice on KF titration.
Metrohm's (Switzerland) free multimedia guide is based on the installation manual of our new Karl Fischer titrator, the 870 KF Titrino plus. It draws on the comprehensive know-how of their specialist in KF titration and is intended for experienced staff and beginner alike. Plenty of video custscenes and animated illustrations make watching the DVD a pleasure. Not only do you learn how to set up your KF titration cell correctly, but also how to use your KF standards.
Getting difficult samples into the titration cell can be challenge. Our specialists give you practical tips how to best add solid, liquid or viscous samples in to the KF titration cell.
Do you know the perfect pH for Karl Fischer titration? what's the difference between a one-and a two-component reagent? The comprehensive glossary explains the basics of KF titration and the most frequently used term. Don't hesitate - ask your Metrohm sales represntative for your free copy of the Metrohm multimedia guide for Karl Fischer titration today.
Posted by besar at 10:56 PM 0 comments
Tuesday, September 8, 2009
Determination of Melamine in Food by Ion Chromatography
Metrohm has released a simple and accurate method for the determination of melamine in milk powder and other food using ion chromatography after inline sample dialysis. The new method requires only moderate spending on instrumentation and is sensitive enough to quantify melamine content well below the limits set by food safety regulatory authorities around the world.
Melamine is an industrial chemical in the production of resins, which are used in laminates, glues, adhesives, and plastics. It has won a sad notoriety as an illict adulterant to simulate higher protein levels in milk powder and other food.
The new method to detect melamine contamination in food relies on the high accuracy and sensitivity of the 884 UV/VIS Compact IC, Metrohm's all-in-one system for the spectrophotometric determinatin of polar subtances, anions, and cations. Sample preparation is perfectly convenient due to Metrohm's patented inline sample dialysis. This kind of Metrohm inline sample preparation effectively eliminates the organic matrix. The new metrohm IC application work on the determination of melamine in food by ion chromatography can be downloaded at www.metrohm.com
Posted by besar at 8:39 PM 0 comments
Digital Ceramic Top Hot Plate Stirrers Family
The new Ceramic Top Hot Plate Stirers Family AREC, AREC.X and AREC.T from Velp Scientifica (Italy) are provided with a reflective white ceramic top (it can reach up to 540 C in a just few minutes!), excellent for observing changes of colour (e.g. titrations,...) as well as highly resistant to alkali/acid corrosion, scratches, compatible with metallic containers and easy to clean.
Innovative design with control panel separated from the ceramic top, assuring complete safe operations. The bright red digital display visualizes repeatable and accruate temperature settings and stirring function on/off.
Safety features include a "Hot Plate" digital warning sign which is constantly displayed during operations when the temperature is above 50 C and flashes when the unit is switched-off until the temperature cools below 50 C.
Posted by besar at 7:36 PM 0 comments
The ThermaCAM GasFind IR LW Sees Sulphur Hexafluoride (SF6)
This success has led to further product development and the introduction of an infrared camera specifically for detecting greenhouse gasesthet are not visible in the mid-wave infrared band; Sulphur hexafluoride and anhydrous ammonia are typical examples. This new camera is the ThermaCAM GasFind IR LW. It is based on the standard model but as its suffix suggest it operates in the longwave infrared band.
Sulphur hexafluoride (SF6) is a relatively expensive man-made chemical released by electrical substations where it is used as an electrical insulator in equipment that transmits and distributes electricity. It is also used as a cover gas in the magnesium industry, in the manufacture of semiconductors, for thermal and sound insulation, as a tracer gas for vebtilation efficiency and in medical applications. Although Sulphur hexafluoride is extensively recycled leakage is still a concern. excessive exposure can harm human health and of the internationally monitored greenhouse gases it has, by far, the greatest global warming potential- 23,000 times that of CO2. This gas is included in the European Pollutant Emission register, a vast database that catalogues European industrial pollution. It requires affected industrial plants to indentify leaks from a range of 50 pollutants that they emit into the air or water in quantites over a given threshold. The ThermaCAM GasFind IR LW allows plant managers to see, and hence, reduce the emission of SF6 with ease. Although the detection of Sulphur hexafluoride is a key selling point for this new camera it is not by any means the only gas that it can detect. It is designed to see a wide range of other gases too including anhydrous ammonia tha is widely used as a refrigerant in large cold-storage facilities.
The new ThermaCAM GasFind IR LW actually shows any leakage point or points of SF6 gas in real time. It can detect small leaks from several metres away and big leaks from hundreds of metres away and in trials has proved able to see leaks that have eluded a traditional active laser system. In addition to making leaks visible, the camera is able to scan large areas quickly, greatly increasing inspection speed and improving overall plant safety. It can also be used without stopping any operation or process
WolfPack Area Monitor for indoor Air Quality (IAQ)
Available parameters include : TVOCs, Carbon Dioxide, %RH, 'C/'F, particulates, auto-zeroing Differential Pressure and Air Velocity. sensors for these parameters all exhibit rapid response and are highly accurate. In addition, up to 18 specific electrochemical gas sensors (CO, O3, NH3, NO2, NO, H2S, SO2, Cl2, HCN, HCl, etc) are available.
The WolfPack has a tactile color screen and is powered by an embedded WinCE operating system running GrayWolf's 2009 application software. Wolfsense 2009 offers a broad range of user-friendly features . A unique workflow feature handholds users through data-logging set-up; easily costumized for very specific applications, allowing less experienced operators to take advantage of more advanced functions. On-board features also include: Video help, Parameter details (typical source, typical background levels, health effects,etc..), sensor info (basic sensor care, cross-interferences, specifications,etc), application related documents, In-situ text notation, In-situ audio notation..and much more.
Once measurements have been trend-logged over time; review, analyze, and report on the data and field-collected notes with the included WolfSense PC software. Optional Advanced report generator software automates the entire reporting process.
H2Scan Corporation Receives The Korea Occupational Safety & Health Agency (KOSHA) Certificate
H2scan's Vice President of Sales and Business Development Cyril Berg stated, "Having these two units receive the KOSHA certificated of Compliance in addition to their current ATEX certification is an important step for us to penetrate the Korean market. It will provide us and our Korean distributor, young heung coporation, the necessary leverage in selling these product."
H2scan's HY-ALERTA 1600 intrinsically Safe Area Hydrogen Monitor provides fixed area hydrogen specific measurement for hydrogen concentrations as low as 4000 ppm and can be scaled to any concentration up to 5% hydrogen by volume. Additionally, its hydrogen specific sensor technology has no cross sensitivity to other combustible gases, thus eliminating false alarms and ensuring safety system reliability. With a 10 year product life expectancy, it also proves to be fiscally prudent.
Thermo Fisher Scientific Launch Compact Modular Total Nitrogen/Sulfur/Chlorine Analyser
In order to ensure optimum productivity within today's global market, the fast reporting of total sulphur, nitrogen and chlorine content data, coupled with superior analytical is essential. Traditional analysers achieve times of six minutes, requiring extra carrier gas facilities and frequent system check, the innovative thermo Scientific TITAN 4000 NSX analyser is capable of analysing TN/TS samples within an unsurpassed two minutes and TX samples in under four minutes.
By operating in real time and with minimal sample handling requirements, the TITAN 4000 analyser decreases analytical cost and complies with current market driven ASTM, IP and UOP methods. The powerful new analyser features a unique, patent-pending chromium plated copper spray injection design, which is able to inject high boiling point component samples without blocking the injection system. The sample introduction and combustion technology, with pre-soot detection(patent pending), ensures optimum analysis and result precision, reducing lead time and minimising matrix effect.
Contrary to other technologies , The TITAN 4000 injection port and the plugflow quartz combustion tube require only oxygen gas. Maintenance is reduced through removing the need for their frequent replacement. A heated filter and a number of gasflow and temperature control sensors further eliminate the need for user interaction. These features improve the autonomy of the system and reduce instrument downtime and maintenance. minimising operation costs associated with gas consumption and consumables. In addtion, the combination of safe, sensitive and realiable TS-UVF, TN-CLD, microcoulometric techniques and reduced instrument interaction lead to heightened laboratory safety.
Free Multimedia Guide for Karl Fischer Titration
Metrohm's (Switzerland) free multimedia guide is based on the installation manual of our new Karl Fischer titrator, the 870 KF Titrino plus. It draws on the comprehensive know-how of their specialist in KF titration and is intended for experienced staff and beginner alike. Plenty of video custscenes and animated illustrations make watching the DVD a pleasure. Not only do you learn how to set up your KF titration cell correctly, but also how to use your KF standards.
Getting difficult samples into the titration cell can be challenge. Our specialists give you practical tips how to best add solid, liquid or viscous samples in to the KF titration cell.
Do you know the perfect pH for Karl Fischer titration? what's the difference between a one-and a two-component reagent? The comprehensive glossary explains the basics of KF titration and the most frequently used term. Don't hesitate - ask your Metrohm sales represntative for your free copy of the Metrohm multimedia guide for Karl Fischer titration today.
Determination of Melamine in Food by Ion Chromatography
Melamine is an industrial chemical in the production of resins, which are used in laminates, glues, adhesives, and plastics. It has won a sad notoriety as an illict adulterant to simulate higher protein levels in milk powder and other food.
The new method to detect melamine contamination in food relies on the high accuracy and sensitivity of the 884 UV/VIS Compact IC, Metrohm's all-in-one system for the spectrophotometric determinatin of polar subtances, anions, and cations. Sample preparation is perfectly convenient due to Metrohm's patented inline sample dialysis. This kind of Metrohm inline sample preparation effectively eliminates the organic matrix. The new metrohm IC application work on the determination of melamine in food by ion chromatography can be downloaded at www.metrohm.com
Digital Ceramic Top Hot Plate Stirrers Family
Innovative design with control panel separated from the ceramic top, assuring complete safe operations. The bright red digital display visualizes repeatable and accruate temperature settings and stirring function on/off.
Safety features include a "Hot Plate" digital warning sign which is constantly displayed during operations when the temperature is above 50 C and flashes when the unit is switched-off until the temperature cools below 50 C.