Monday, December 7, 2009

Pressurised Solvent Extraction Taken to a New Dimension

The main focus of modern analytical laboratories is minimising the time that elapses between sample analysis and result generation. Even today, despite modern extraction techniques, the extraction process can be very time consuming. Thanks to unique design of Buchi's (Switzerland) new Speed Extractor, pressured solvent extraction is taken to a new dimension. With its parallel format, up to six samples can be extracted simultaneously in approximately 20 to 40 minutes. As a result, incoming batches can be processed immediately and the analysis results is available on the same day if subsequent extensive purification steps are required. This allows for a previously unheard level of efficiency and throughput: up to 96 samples in one work day.

The Speed Extractor also distinguishes itself by its user-friendliness: The desired method is loaded, the extraction cells are then sealed automatically, and at the push of a button, six samples are extracted - no error-prone sealing, no time-consuming programming.
The Speed Extractor flexibility is unique as well : Temperature range of 50 - 200'C, pressure range of 50 - 150 bar, extraction cell size of 10 - 120 ml, 60 ml, 220 ml, and 240 ml collection vessels, and an integrated rinsing step into a separate waste container. A large selection of process parameters allows for a new standard in the number of supported applications.

0 comments:

Pressurised Solvent Extraction Taken to a New Dimension

The main focus of modern analytical laboratories is minimising the time that elapses between sample analysis and result generation. Even today, despite modern extraction techniques, the extraction process can be very time consuming. Thanks to unique design of Buchi's (Switzerland) new Speed Extractor, pressured solvent extraction is taken to a new dimension. With its parallel format, up to six samples can be extracted simultaneously in approximately 20 to 40 minutes. As a result, incoming batches can be processed immediately and the analysis results is available on the same day if subsequent extensive purification steps are required. This allows for a previously unheard level of efficiency and throughput: up to 96 samples in one work day.

The Speed Extractor also distinguishes itself by its user-friendliness: The desired method is loaded, the extraction cells are then sealed automatically, and at the push of a button, six samples are extracted - no error-prone sealing, no time-consuming programming.
The Speed Extractor flexibility is unique as well : Temperature range of 50 - 200'C, pressure range of 50 - 150 bar, extraction cell size of 10 - 120 ml, 60 ml, 220 ml, and 240 ml collection vessels, and an integrated rinsing step into a separate waste container. A large selection of process parameters allows for a new standard in the number of supported applications.

0 comments:

Post a Comment