Prepare your AOX samples overnight : The behr Labor-Technik GmbH (Germany) PXS 24 AOX auto sampler is suitable for the preparation of up to 24 samples according to the EN 1485/ISO 9562 column method. A high precision pump supplies each activated carbon column with the exact sample volume. With the PXS 24 AOX auto sampler the analyst can use industry standard adsorption columns as well as his own manually filled columns. The auto sampler works fully automatically. manual operations are reduced to : insertion of the sample flask into the rack, insertion of the mini adsorption columns into the adapter and attachment of the adapter to the mounting bar.
Control of the auto sampler is performed by user-friendly Windows software. Once entered, the data can be transferred directly to the behr Cl 10 analyser. Analyser and auto sampler are controlled simultaneously by the same PC. The analyst can enter sample volume and flushing volume individually for each sample. Analysis data are entered into a table, which can be instantly used for the final analysis of the samples.
A pump transfers the samples from the sample bottles to the activated carbon columns. Each sample is delivered to its corresponding adsorption column by a 25 port valve. Following adsorption you can freely adjust he volume of the nitrate solution for the final flushing of the system. Features of the bahr PXS 24 AOX auto sampler :
Sample contact only with inert materials (glass, PTFE, PVDF, Steel). Simple insertion of the adsorption columns. No memory effects. Stirring during removal of the samples. Operates with particle sized up to 2 mm. Safety of pump motor is controlled by light barrier. Pre-filter plus 2 adsorption columns. The rack takes standard sample flasks.
Thursday, October 15, 2009
PXS 24 AOX Autosampler for the Preparation of up to 25 Samples
Posted by besar at 7:34 PM
Labels: Environmental Analysis Tool
Subscribe to:
Post Comments (Atom)
PXS 24 AOX Autosampler for the Preparation of up to 25 Samples
Posted by
besar
on Thursday, October 15, 2009
Labels:
Environmental Analysis Tool
Prepare your AOX samples overnight : The behr Labor-Technik GmbH (Germany) PXS 24 AOX auto sampler is suitable for the preparation of up to 24 samples according to the EN 1485/ISO 9562 column method. A high precision pump supplies each activated carbon column with the exact sample volume. With the PXS 24 AOX auto sampler the analyst can use industry standard adsorption columns as well as his own manually filled columns. The auto sampler works fully automatically. manual operations are reduced to : insertion of the sample flask into the rack, insertion of the mini adsorption columns into the adapter and attachment of the adapter to the mounting bar.
Control of the auto sampler is performed by user-friendly Windows software. Once entered, the data can be transferred directly to the behr Cl 10 analyser. Analyser and auto sampler are controlled simultaneously by the same PC. The analyst can enter sample volume and flushing volume individually for each sample. Analysis data are entered into a table, which can be instantly used for the final analysis of the samples.
A pump transfers the samples from the sample bottles to the activated carbon columns. Each sample is delivered to its corresponding adsorption column by a 25 port valve. Following adsorption you can freely adjust he volume of the nitrate solution for the final flushing of the system. Features of the bahr PXS 24 AOX auto sampler :
Sample contact only with inert materials (glass, PTFE, PVDF, Steel). Simple insertion of the adsorption columns. No memory effects. Stirring during removal of the samples. Operates with particle sized up to 2 mm. Safety of pump motor is controlled by light barrier. Pre-filter plus 2 adsorption columns. The rack takes standard sample flasks.
Control of the auto sampler is performed by user-friendly Windows software. Once entered, the data can be transferred directly to the behr Cl 10 analyser. Analyser and auto sampler are controlled simultaneously by the same PC. The analyst can enter sample volume and flushing volume individually for each sample. Analysis data are entered into a table, which can be instantly used for the final analysis of the samples.
A pump transfers the samples from the sample bottles to the activated carbon columns. Each sample is delivered to its corresponding adsorption column by a 25 port valve. Following adsorption you can freely adjust he volume of the nitrate solution for the final flushing of the system. Features of the bahr PXS 24 AOX auto sampler :
Sample contact only with inert materials (glass, PTFE, PVDF, Steel). Simple insertion of the adsorption columns. No memory effects. Stirring during removal of the samples. Operates with particle sized up to 2 mm. Safety of pump motor is controlled by light barrier. Pre-filter plus 2 adsorption columns. The rack takes standard sample flasks.
1 comments:
- Unknown said...
-
These are some great tools that i definitely use for SEO work. This is a great list to use in the future..
knauer autosampler - September 7, 2017 at 4:29 AM
:f :D :) ;;) :x :$ x( :?
:@ :~ :| :)) :( :s :(( :o
1 comments:
These are some great tools that i definitely use for SEO work. This is a great list to use in the future..
knauer autosampler
Post a Comment